ISO/IEC 14443 Type B-Compliant
64-Bit UID
Response Information Field for the Get System Information Command (No Error)
INDICATOR
00h
INFO
FLAGS
0Fh
UID
(8 Bytes)
(DUMMY)
(1 Byte)
AFI
(1 Byte)
NUMBER OF
BLOCKS
02h
MEMORY BLOCK
SIZE
07h
IC REFERENCE
(1 Byte)
Response Information Field for the Get UID Command (No Error)
INDICATOR
00h
Detailed Command Descriptions
Get System Information
This command allows the master to retrieve technical
information about the MAX66000. In the response, the
least significant UID byte is transmitted first. The
response is adapted from ISO 15693-3, Section 10. The
IC reference code indicates the die revision in hexa-
decimal format, such as A1h, A2h, B1h, etc. To receive
the system information, issue a request with the com-
mand code 2Bh in the request information field.
Get UID
This command allows the master to retrieve the
device ’s unique identification number, UID. In the
response, the least significant UID byte is transmitted
first. To read the UID, issue a request with the com-
mand code 30h in the request information field.
UID
(8 Bytes)
ISO/IEC 14443-3 Type B Initialization
and Anticollision Protocol
Before an ISO/IEC 14443-compliant RF device gives
access to its memory, a communication path between
the master and the RF device must be established.
Initially, the master has no information whether there are
any RF devices in the field of its antenna. To find out
whether there are one or more RF devices compliant to a
known standard in the field, the master uses a standard-
specific initialization and anticollision protocol. The
ISO/IEC 14443 Type B protocol defines six states:
POWER-OFF, IDLE, WAITING FOR SLOT-MARKER,
READY, HALT, and ACTIVE. Figure 16 shows these
states and the conditions under which a slave transitions
between states. For most cases, letters surrounded by
small circles reference the condition under which a tran-
sition occurs. The conditions are explained in the legend
to Figure 16. Table 1 explains terms that are used in the
anticollision protocol and in the network function com-
mand description.
8
_______________________________________________________________________________________
相关PDF资料
MAX66020K-000AA+ IC RFID UID 1KB TYPEB MEM KEYFOB
MAX66040K-000AA+ ISO CARD SECURE MEMORY
MAX6605MXK/V+T IC TEMP SENSOR ANLG LP SC70-5
MAX6608IUK+T IC TEMP SENSOR ANLG SOT23-5
MAX66100K-000AA+ IC RFID UID 64BIT TYPE B KEY FOB
MAX6611AUT+T IC TEMP SENS LOW PWR SOT23-6
MAX66120K-000AA+ IC RFID UID 1KB TYPEB MEM KEYFOB
MAX6612MXK+T IC TEMP SENSOR ANLG SC70-5
相关代理商/技术参数
MAX66000K-00AA+ 制造商:Maxim Integrated Products 功能描述:ISO/IEC 14443 TYPE B-COMPLIANT 64-BIT, UID FOB - Rail/Tube
MAX66020K-000AA+ 功能描述:RFID应答器 ISO/IEC 14443 Type B Comp 1Kb Mem Fob RoHS:否 制造商:Murata 存储容量:512 bit 工作温度范围:- 40 C to + 85 C 安装风格:SMD/SMT 封装 / 箱体: 封装:Reel
MAX66020K-00AA+ 制造商:Maxim Integrated Products 功能描述:ISO/IEC 14443 TYPE B-COMPLIANT 1KB MEMORY FOB - Rail/Tube
MAX6602UE9A+ 功能描述:板上安装温度传感器 5Ch Precision Temperature Monitor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6602UE9A+T 功能描述:板上安装温度传感器 5Ch Precision Temperature Monitor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6603ATB 制造商:Maxim Integrated Products 功能描述:DUAL-CHANNEL PLATINUM RTD-TO-VOLTAG - Rail/Tube
MAX6603ATB+ 制造商:Maxim Integrated Products 功能描述:RTD TO VOLT SGNL CONDITIONER 10TDFN EP - Rail/Tube
MAX6603ATB+T 功能描述:板上安装温度传感器 RTD-to-Voltage Signal Conditioner RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor